New, very user friendly stimulator with precise search function and digital display. Acupuncture and trigger points are stimulated with electricity of different polarities (tonic and sedative). As a result, acute and chronic pain eased and post-operative processes are supported.
Product features: - Highly portable and easy - Comfortable to use anatomical shaping - With sensitivity, power and polarity control - Beep, light-signaling and digital display provide frequency and sensitivity to - Two interchangeable tips (for body and ear acupuncture) - Direct stimulation of acupuncture points
Technical details: - Output current: 0-22 mA - Frequency: adjustable from 1 to 16 Hz - Pulse shape: continuous pulse shape - Pulse width: 220 microseconds - Polarities switch: (+/-) - Dimensions: 17 x 3.3 x 2.3 cm - Weight: 60 g - Total weight (with plastic box): 230 g - Power supply: 1 9-volt battery
Delivery: - 1 POINTER EXCEL II - 1 ground electrode - 2 interchangeable tips (for the ear and body acupuncture) - 1 plastic box - 1 9-volt battery - 1 eng. instruction manual
The POINTER EXCEL II is NOT a medical device.
OPERATION STEPS 1. One sensitivity (SEN) control knob on the right hand side of the unit to control the sensitivity. Base on different skin to adjust it. 2. An intensity (INT) and ON/OFF control knob on the left hand side of the unit to control the intensity of the output through the metal probe electrode, which is located at the front tip of the unit. 3. A push type button on the front top of the unit. Press this button to activate the stimulation mode. A continuous electric pulse of 1 to 16 Hz (adjustable) is emitted through the metal probe. 4. Frequency adjustment dial, located under the sensitivity (SEN) control knob, to adjust the frequency of stimulation from 1 Hz to 16 Hz. 5. The digital Display Screen is located on the rear top side of the unit. It features numerical display (0 to 500) to remind user if find the acupoint or not . the larger number is mean more closer the acupoint. 6. There is a green pilot lamp on top of the unit, next to the push type button (LOC/STIM). This will continue light up when find the acupoint or stimulation mode is in action. 7. Two ground plates, one located at the front left hand side, and the other one underneath the unit, allow the user to hold the unit and touch the ground plate(s) easily in closing the circuit for point detection or stimulation. 8. There is one jack on the bottom side of the unit. This is for connecting the electro pad (Ashi Pad). 9. The Digital Display chamber is located on the rear to side of the unit. Show the number from 0 to 500 , When used in Acupuncture or trigger point detection , the highest numerical value refers to the nearest site of acupuncture point.Also the green indication LED will remain lit when the acupuncture point was found. 10. Acupuncture treatment through the probe can be used for the immediate treatment of the point or area right after its detection to the patient, by simply pushing down the stimulation/detection button on top of the unit. Activate the stimulation mode. A continuous electric pulse of 1 to 16 Hz (adjustable by turning the frequency dial) is emitted through the probe, the intensity and sensitivity may also be adjusted from 0 to 10ma. The intensity is controlled with the intensity knob labeled “INT”. the sensitivity is controlled with the sensitivity knob labeled “SEN”. Micro current intensity is emitted when the switch is in the “blue” zone. When treating with micro current intensity, there will be very little or no feeling of stimulation achieved even the probe is located at the trigger or acupuncture points. 11. Modern Spring Type Probe Tip with new improved interchangeable spring type probe provides a more constant and comfortable acupressure to the area or points, thus providing better accuracy during point location searching. It is important to note that any part of the body may be induced to produce a point location signal depending on the amount of pressure used during location. Thus, it is important when locating the trigger points to use the least amount of pressure possible on the surface of the skin. Also, the movement of the probe when searching for the point should be smooth and graceful, always maintaining the same light uniform constant pressure until the correct point is found. The unique spring mechanism of the Pointer probe will add in correction for any slight variations in the applied pressure.
|